ion cleanse,ion dotex,footspa,foot spa,spa,footbath,foot bath,bath spa
ion dotex,footspa,foot spa,spa,footbath,foot bath
Return homepage,Guangzhou sanhe specialized production ion cleanse.
The product is introduced.
Company culture. Footbath,foot bath,bath spa,ionic footbath
Company certificate. Ion cleanse,ion dotex,footspa,foot spa,spa
Project. Footspa,foot spa,spa,footbath,foot bath,bath spa
Policy. Footspa,foot spa,spa,footbath,foot bath,bath spa
Contact. Footbath,foot bath,bath spa
Online messages for us.
IE Favorites
TXT download
Guangzhou sanhe new product recommend. Ion cleanse,ion dotex,footspa
Detox system
About GUANGZHOU SANHE ELECTRONIC TECHNOLOGY CO. ,LTD. Foot spa,spa,footbath,foot bath,bath spa
     Sanhe Electronic Technology Co.,Ltd (headquarters in the southern of China- -Guangzhou City Guangdong Province) is a productive enterprise which privately owned large-scale and high-tech with independent research and develope ability, we mainly develope SCM business, and offer OEM-ODM services for our clients. as one of the first-class electronic manufacturing enterprises of China. we get the recognized by the international market,and our products have already found a good sale to Southeast Asia, Australia, America and Europe etc. We have a large-scale production basic in Guangzhou . The equipments of factory is advanced,computer automalization management.More than 90% of our staff have academic or above qualification. we can independently produce electron apparatus. Our products cover fields in beauty and health care,coin washing machine and home electronic product etc. We have complete test systerm, research , production and marketing management group. In the past few years, we have experienced great development in scientific and technical innovation, manufacturing, market exploring,and technical service,etc.,our product have passed the CE,PSE.

Model No.:K800
Power consumption: 35W
Oxygen concetration:Approx .30%(at 20鈩?
Airfolw rate:Approx .2L/min.(at 20鈩?




K2008 Oxygen concentrator


Operation Instructions


Contents


1)Before using


Safety precautions


Principle of operation


Names of parts


2)How to operate


How to use


3)When required


How to maintain


Daily maintenance


Specifications


 


Safety precautions


In order to prevent the risk of danger to the operator of this product or those nearby, and damaging property, be sure to follow the safety precautions outlined below.


? The following terms are used for precautions. They are separated depending on the degree of the danger or damage that may occur if their contents are ignored while using this product.


 


This term cautions you that injury or physical damage to property may result may result by incorrect operation of the product.


This term warms you that death or serious injury may result by incorrect operation of the product.


The following signs are used to explain operations that you are requested to follow. They are separated as shown below. (Below are examples of the signs used in this manual.)


This sign designates actions that you must never do (prohibited actions).


This sign designates actions that you must do (required actions).


 


NOTE


Do not the components with the air of an electric dryer, etc. (It may cause deformation or failure.)


1.Reassemble the components.


NOTE


* Be sure to mount the filter before use.


Mounting the O2 mouthpiece


The orientation (front or back) is not an issue for the filter.



Specifications









































Model No.


K800


Power consumption


35W


Oxygen generating method


Membrane separation method


(oxygen entichment membrane)


Inhalation method


Using a O2 headset (Back-hanging type)


Oxygen concetration


Approx .30%(at 20鈩?


Airfolw rate


Approx .2L/min.(at 20鈩?


Continuous operation time


1-/20/30 minutes with a timer


Operation noise


Approx .50dB


Dimensions


W168 mm脳D240mm脳H209mm


Weight


4kg


Accessories


O2 headset---------1set


Tube set---------1set


AC Adaptor---------1set


 


Daily maintenance


CAUTION


Maintenance required when odor and dirt become annoying or after a long period of disuse.


Maitenance on O2 headset and tube set


1. Remove the capsule and tube.(Leave the capsule and tube mounted except when performing maintenance.)


2. Remove the mouthpeiece, filter, and the mouthpiece cap.


 


Removing the O2 mouthpiece


Pull out the mouthpiece slowly the direction shown by the arrow.


 



Daily maintenance


3. Rinse the coponents. * Soak the coponents in water for 2 to 3 minutes and let water go thorugh the tube.



NOTE


路Do not soak the components in water that is hotter than 60鈩? (Otherwise, it causedeformation or discoloring.)


路Do not rinse the whole O2 headset.


路Do not use detergent, benzene, thinner, or alcohol.(Otherwise, it may cause deformation or disclolring.)


路Be careful not to lose the filter, which are small.


 


4. Dry the coponents


1) Wipe out and drain off the moisture.


2) Mount the components on the unit as shown in thefigure on the fight and operate for 30 minutes to dry out the unit.


3)Remou the O2 headset, capsule and tube and dry them copletely in a celan place in direct sunlight.(If drying is incoplete, water may drip out of the O2 mouthpiece during operation.)


CAUTION












Do not operate the appliance when a fumigating (smoking) type insecticide is used in the room.


Otherwise, an accumulating active coponet of the insecticide may be discharged by operation of the appliance, and this may harm your health.


*After using insecticede, be sure to provide sufficient ventilation before using the apppliance.


**Keep the appliance away fom any flame. Deformation of the unit may cause shorting of ignition.


**Pull out the plug when the appliance is not used for a long time.


Otherwise, it may cause injury, burn, electric shock due to insulation foilure, or fire caused by leakage.


*Be sure to hold the plug properly when puling it out.


Otheerwis, it mya cause electric shock or ingitoin caused by shorting.


**Do not use the appliance in a most place such as a bathroom or a sauna bath.


Otherwise, it may cause an electric shock or falure.


 


 


WARNING
















*Do not let an unsophisticated user such as a child oerate the appliance alone.


Do not palce the appliance within reach of babies and toddlers.


A tube tsisting aroudn the neck may cause choking, or an O2 mouthpiece may be swallowed.


*Be care not to damage the pewer card an plug.


Operating with a damaged cerd or a fire.


*Contact your dealer to repair a cord or plug.


*Do not soak the unit in water, and do not spill water over the unit.


Otherwise, it may cause an electric shock, a short circeit, or a fire


*Do not disassemble, repair, or modify the appliance.


Ignition or abnormal operation may cause serious injury.


*Contact your dealer for repair.


*Never remove or in stall the plug with wet hands.


May cause an electrical shock.


*Be sure to pull out the plug before maintenance and inspection.


Otherwise,it may cause an electric shock or injury.


**Provide proper ventilation when using the appliance with combusting equipment.


Otherwise,it may cause carbon monxide poisoning.


This appliance does not remove toxic gases such as carbon monxide.


 


*Remove the dust on the plug regularly.


Dust accumulation on a plug may cause poor insulation and a fire.


Pull our the plug and wipe it regularly with a dry cloth.


 


 


Frequent maintenece


Empty the capsule if water is accumulated in it .Wipe off droplets with a facial tissue or something similar.


If too much water a ccumulates in the capsule,water droplets may come out of the O2 mouthpiece.


 


If water adheres to filter,remove the filter and dry it in the shade in a clean place.


Before use ,dry the filter completely.Absorbing water with tissue paper helps to dry the filter.


(Refer to page 14,15,16 for removel procedures for the filters.)


If you use the Oxygen Concentrator continuously of at a time or place of high humidty,water will accumulate more quickly.


 


NOTE


*Please do not drink the water which accumulated.


 


How to maintain


Periodic maintenance (approximately once per month)


*You may remove the filer and wash it with water.


After washing it ,dry the filter completely before attaching it to the main unit.


NOTE


*After the maintenace ,be sure to attach the filter before use.



 


 


When the 鈥淧ower on/Time鈥?button is pressed,the LED display 鈥?/STRONG>鈥?and the O2lamp inllumintes at the same time 30% oxygen-rich iair is discharged from the O2 mouthpiece.


 


Each time you press the 鈥淧ower on/Time鈥?button the time setting is shifted from 10 minrtes to 20 minutes and to 30 minutes to 20minutes and to 30 minutes in the order.



 


Basically,we recommend that you use this product for about 10 munites every day,but you may change the setting to 20 or 30 munutes or no timer (At display )


 


*When the sel time is over. The machine鈥檚 opertion stops automatically.


 


 


How to use


 


Airflow speed selection


 


*The airflow speed can be switched between two levels.


(The airfolw volume is constant regardless of the airflow speed selection.)


*Hold the mouthpiece as shown in the figure and select the airflow speed.


(Do not block the air outlet port.)



 


CAUTION


When storing the appliance for a long time.


Before storing, operate the appliance for 30minutes on a dry day to dry the tube and capsule copletely.


 


 


How to maintain


 


CAUTION


Before starting the maintenance, press the 鈥渙ff鈥?button and disconnect the power plug.


 


 


Names of parts



 



About the usage environment


The reconnended temperature of the roon where you use this procuct is between 10 to 30鈩?Although oxygen is slight ly thicker a lower temperatures,resulting in a lower airflow rate;at higher temperatures,oxygen is thinner and the airflow rate is higher.


If operrated near a radio,product may cause noise and make if difficult tolisten to the radio use it at least on mater away from radio.


 



  • Wear the O2 headset and get the O2 mou thepiece ready.

路Adjust the band length of the O2 headest.


路Fix the O2mouthpiece at about 1 to 3cm from your nose.


(As shown in the figure below, adjust the position of the air outlet port of the O2 headset.)


NOTE


路If your lips get too dry as result of the airflow from the O2mouthpiece,please use some lip cream,moisturizing cream,etc.


路Be carefull not the bend the tude.


If the tube is bent and there is not proper airflow,the airflow,the tube at the air outlet of main unit is disconnected.If the is happens,insert the tube again as far as it will go.


銆圗xamples of O2headset wearing styles銆?/P>

Wear the headset so you feel at case depending on your position and place of use.



At the beginning ,you may sense the small of the product鈥檚,but this smell wil lfade away as you use the product.


 


Insert the power plug an electric outlet and Press the 鈥淧ower On/Timer鈥?Button to operate.



Warranty Information Card


This warranty covers defects in material and workmanship for one year from the original date of delivery. We will replace any part which in our opinion is defective; if the housing has not been subjected to tampering, alteration, or improper use after delivery and has not been repaired by anyone accept us. Our obligation does not include the cost of transportation. We are not responsible for damage in transit, and claims for such damage should be presented to the carrier by the customer. The housing is not warranted against misuse or use in abnormal temperature conditions.


For servicing under this warranty, return any defective part to YOUR DISTRIBUTOR within the period listed below.


 


 


Warranty Registration Card


To register warranty for this product, complete the information below.


Name


Address


City/State/Zip


Telephone


Date Purchased